Product Overview
Technical Summary
| Product designation | 1PH8101-1MF12-2BA1 |
|---|---|
| Product family | SIMOTICS M compact asynchronous motor |
| 1500 r/min rating | 3.7 kW, 24 Nm, 12.5 A, 265 V |
| 1750 r/min rating | 4.3 kW, 23 Nm, 12.5 A, 304 V |
| 2000 r/min rating | 4.7 kW, 22 Nm, 12.5 A, 343 V |
| 2200 r/min rating | 5.1 kW, 22 Nm, 12.5 A, 363 V |
| Feedback | Incremental encoder SIN/COS 1 VPP 2048 S/R with C and D track |
| Temperature sensor | KTY 84-130 |
| Cooling | Forced ventilation; air flow direction NDE–> DE |
| Mounting | Design IM B5 (IMV 1,IM V3) |
| Protection | IP55 degree of protection |
Key Features
- Motor designation: SIMOTICS M compact asynchronous motor with multiple supplied speed, power, torque, current, and voltage ratings.
- Rated performance: At 1500 r/min: 3.7 kW, 24 Nm, 12.5 A, 265 V; at 1750 r/min: 4.3 kW, 23 Nm, 12.5 A, 304 V; at 2000 r/min: 4.7 kW, 22 Nm, 12.5 A, 343 V; at 2200 r/min: 5.1 kW, 22 Nm, 12.5 A, 363 V.
- Encoder and temperature sensor: Incremental encoder SIN/COS 1 VPP 2048 S/R with C and D track, encoder IC2048S/R, and temperature sensor KTY 84-130.
- Cooling and protection: Forced ventilation with air flow direction NDE–> DE and IP55 degree of protection.
- Mounting and shaft: Design IM B5 (IMV 1,IM V3) with a shaft with fitted key and HALF-KEY BALANCING.
- Connections and bearing: Terminal box above, cable entry on the right, signal connection D-END; bearing is standard with fixed bearing.
Frequently Asked Questions
Which performance ratings identify Siemens 1PH8101-1MF12-2BA1?
The supplied ratings are 3.7 kW at 1500 r/min, 4.3 kW at 1750 r/min, 4.7 kW at 2000 r/min, and 5.1 kW at 2200 r/min, with the corresponding torque, current, and voltage values listed for each speed.
What encoder and temperature-sensor details should be checked?
Check the incremental SIN/COS 1 VPP 2048 S/R encoder with C and D track, encoder IC2048S/R, and KTY 84-130 temperature sensor.
Which mounting, cooling, and protection details identify this variant?
The motor has forced ventilation, air flow direction NDE–> DE, IP55 protection, and Design IM B5 (IMV 1,IM V3).
What connection details should be checked before quotation?
Check the terminal box above, cable entry on the right, signal connection D-END, and the complete 1PH8101-1MF12-2BA1 code.