Product Overview
Technical Summary
| Product code | 1FK7064-4CF71-1FH1 |
|---|---|
| Product family | SIMOTICS S |
| Motor type | Permanent-magnet synchronous motor; High Dynamic |
| Optimum power | 2.5 kW |
| Optimum speed | 3,000 rpm |
| Encoder | AM22DQ absolute encoder, 22 bits + 12 bits multi-turn, DRIVE-CLiQ |
| Mounting design | IM B5 (IM V1, IM V3) |
| Connector size | M23 |
| Holding brake | Permanent-magnet brake; holding torque 13.0 Nm |
| Degree of protection | IP65 |
Key Features
- Product designation: SIMOTICS S permanent-magnet synchronous motor, High Dynamic.
- Optimum power and speed: Optimum power: 2.5 kW; optimum speed: 3,000 rpm.
- Encoder feedback: AM22DQ absolute encoder with 22 bits, 12-bit multi-turn, 4,194,304 resolution, 4096-revolution traversing range, and DRIVE-CLiQ interface.
- Mounting and shaft: IM B5 (IM V1, IM V3) design with plain shaft and flange 1.
- Connections and brake: Rotatable M23 power connector and rotatable signal and power connectors; permanent-magnet holding brake with 13.0 Nm holding torque.
- Cooling and protection: Natural cooling and IP65 degree of protection.
Frequently Asked Questions
What product does Siemens code 1FK7064-4CF71-1FH1 identify?
It identifies a SIMOTICS S permanent-magnet synchronous motor with High Dynamic motor type and 2.5 kW optimum power.
Which encoder and interface identify this exact variant?
The variant has an AM22DQ absolute encoder with 22 bits, 12-bit multi-turn, and a DRIVE-CLiQ interface.
Which mounting, shaft, and connection details should be checked?
Check the IM B5 (IM V1, IM V3) design, plain shaft, flange 1, and rotatable M23 power connector.
Does this configuration include a holding brake?
It has a permanent-magnet holding brake with 13.0 Nm holding torque.