Product Overview
Technical Summary
| Product designation | Mobile Panel 277 |
|---|---|
| Display | TFT, 7.5 in, color, 640 pixel × 480 pixel, 65 536 colors |
| Operator controls | Keys and touch; 18 function keys with LEDs; analog resistive touch screen |
| Interfaces | 1x RS 422, 1x RS 485, 1x Ethernet (RJ45) (max. 12 Mbit/s), 1 USB |
| Protocols | PROFINET IO, PROFIBUS, EtherNet/IP, TCP/IP, MODBUS |
| Power supply | DC via connection box |
| Configuration | WinCC flexible Standard Version 2005 SP1 or higher or TIA Portal V11 to V14 |
| Memory | Flash / RAM; 6 Mbyte user data; 128 Mbyte maximum main memory |
Key Features
- Product designation: SIMATIC Mobile Panel 277 with integrated acknowledgment button.
- Display: TFT color display with a 7.5 in screen diagonal, 65 536 colors, and 640 pixel × 480 pixel resolution.
- Operator controls: Keys and touch, 18 function keys with LEDs, numeric, alphanumeric, and hexadecimal keyboards, and analog resistive touch operation.
- Interfaces and protocols: 1x RS 422, 1x RS 485, 1x Ethernet (RJ45) (max. 12 Mbit/s), 1 USB interface, and 1 MMC/SD card slot; supports PROFINET IO, PROFIBUS, EtherNet/IP, TCP/IP, MODBUS, and other bus systems.
- Configuration software: Configurable with WinCC flexible Standard Version 2005 SP1 or higher or TIA Portal V11 to V14.
- Power and memory: DC power via connection box; Flash / RAM with 6 Mbyte available for user data and 128 Mbyte maximum main memory capacity.
Frequently Asked Questions
What product does 6AV6645-0CA01-0AX0 identify?
It identifies a Siemens SIMATIC Mobile Panel 277 with an integrated acknowledgment button.
Which specifications distinguish this Mobile Panel 277 variant?
The listed variant has a 7.5 in TFT color display, 640 pixel × 480 pixel resolution, 18 function keys with LEDs, and analog resistive touch operation.
Which interfaces and protocols should be checked against the code?
Check 1x RS 422, 1x RS 485, 1x Ethernet (RJ45) (max. 12 Mbit/s), 1 USB interface, and support for PROFINET IO, PROFIBUS, EtherNet/IP, TCP/IP, and MODBUS.
What should be provided for a quotation request?
Provide the complete order number, required quantity, and destination.