Product Overview
Technical Summary
| Product designation | SIMOTICS S synchronous motor 1FK7-CT |
|---|---|
| Rated power | PN=1.9kW |
| DC-link voltage | UDC=600V |
| Torque | M0=8.5Nm (100K) |
| Rated speed | NN=3000rpm |
| Encoder | Absolute encoder, 32 S/R singleturn, 4096 rotation multiturn |
| Encoder interface | ENDAT; encoder AM32S/R |
| Cooling | Naturally cooled |
| Mounting | Frame size IMB 5 (IM V1, IM V3), flange 1 |
| Shaft | Shaft with fitted key, tolerance N |
| Protection class | IP64 |
Key Features
- Motor designation: SIMOTICS S synchronous motor, 1FK7-CT; PN=1.9kW and UDC=600V.
- Torque and speed: M0=8.5Nm (100K); NN=3000rpm.
- Encoder and feedback: Absolute encoder, 32 S/R singleturn, 4096 rotation multiturn, with ENDAT interface; encoder AM32S/R.
- Mounting and shaft: Naturally cooled; frame size IMB 5 (IM V1, IM V3), flange 1; shaft with fitted key, tolerance N.
- Connections and protection: Power connector rotatable; KTY temperature sensor; protection class IP64.
- Brake and lifecycle: Without holding brake. Product cancellation.
Frequently Asked Questions
Which ratings identify Siemens 1FK7062-2AF71-1GA0?
The sourced ratings are PN=1.9kW, UDC=600V, M0=8.5Nm (100K), and NN=3000rpm.
What encoder and interface does this exact variant have?
It has an absolute encoder with 32 S/R singleturn, 4096 rotation multiturn, and ENDAT interface; encoder AM32S/R.
Does 1FK7062-2AF71-1GA0 include a holding brake?
It is without holding brake.