Product Overview
Technical Summary
| Product designation | SIMOTICS S permanent-magnet synchronous motor, High Dynamic |
|---|---|
| Rated power | 2 kW PN |
| Rated speed | 3,000 rpm (100 K) |
| Rated torque | 6.5 Nm (100 K) |
| Encoder | AS24DQI absolute single-turn encoder, 24 bits, with DRIVE-CLiQ interface |
| Supply voltage | 600 V UDC |
| Mounting design | IM B5 (IM V1, IM V3) |
| Connector | Rotatable M40 connector for signals and power |
| Cooling | Natural cooling |
| Degree of protection | IP65 |
| Holding brake | Without holding brake |
Key Features
- Motor designation: SIMOTICS S permanent-magnet synchronous motor, High Dynamic.
- Rated performance: PN: 2 kW; rated speed: 3,000 rpm (100 K); rated torque: 6.5 Nm (100 K).
- Encoder and interface: Absolute single-turn encoder AS24DQI, 24 bits, with DRIVE-CLiQ interface.
- Mechanical configuration: IM B5 (IM V1, IM V3) design with rotatable M40 connector and Feather key shaft end.
- Cooling and protection: Natural cooling and IP65 degree of protection.
- Brake and monitoring: Without holding brake; Pt1000 temperature sensor.
Frequently Asked Questions
Which ratings identify the Siemens 1FK7086-4CF71-1BA1 motor?
The supplied ratings are 2 kW PN, 600 V UDC, 3,000 rpm (100 K), and 6.5 Nm rated torque (100 K).
Which encoder and feedback interface does this exact variant have?
It has an AS24DQI absolute single-turn encoder with 24 bits and a DRIVE-CLiQ interface.
What mechanical and connection details should be checked?
Check the IM B5 (IM V1, IM V3) design, rotatable M40 connector, and Feather key shaft end.
Does this configuration include a holding brake?
It is without holding brake.