Product Overview
Technical Summary
| Product designation | SIMOTICS M compact asynchronous motor |
|---|---|
| Speed and power ratings | 1500 r/min, 15 kW; 1750 r/min, 17.5 kW; 2000 r/min, 20 kW; 2200 r/min, 22 kW |
| Torque | 96 Nm |
| Current and voltage ratings | 34 A at 342 V, 392 V, 445 V, and 480 V respectively |
| Encoder | Incremental encoder HTL 1024 S/R |
| Temperature sensor | KTY 84-130 |
| Cooling | Forced ventilation; direction of air flow NDE–> DE |
| Degree of protection | IP55 |
| Design | IM B35 (IM V15, (IM V35) |
| Shaft and balancing | Shaft with fitted key; half-key balancing |
| Bearing | Standard with fixed bearing |
| Product lifecycle | Product cancellation |
Key Features
- Motor designation: SIMOTICS M compact asynchronous motor with 1500 r/min and 15 kW rating.
- Speed and power ratings: Ratings include 1500 r/min at 15 kW, 1750 r/min at 17.5 kW, 2000 r/min at 20 kW, and 2200 r/min at 22 kW.
- Torque and electrical ratings: The listed ratings specify 96 Nm and 34 A at 342 V, 392 V, 445 V, and 480 V respectively.
- Encoder and temperature sensor: Incremental encoder HTL 1024 S/R and temperature sensor KTY 84-130.
- Cooling and protection: Forced ventilation with direction of air flow NDE–> DE; IP55 degree of protection.
- Mechanical and terminal configuration: Design IM B35 (IM V15, (IM V35); shaft with fitted key, half-key balancing, standard bearing with fixed bearing, and terminal box above.
Frequently Asked Questions
What product does 1PH8133-1HF13-2BA1 identify?
It identifies a Siemens SIMOTICS M compact asynchronous motor.
Which ratings distinguish this exact variant?
The listed ratings are 1500 r/min at 15 kW, 1750 r/min at 17.5 kW, 2000 r/min at 20 kW, and 2200 r/min at 22 kW, with 96 Nm and the specified voltage and current values.
Which encoder and sensor should be checked?
Check the incremental encoder HTL 1024 S/R and temperature sensor KTY 84-130.
Which mechanical and connection details should be checked?
Check design IM B35 (IM V15, (IM V35), the fitted-key shaft, terminal box above, cable entry on the right, and signal connection D-END.
What details are needed for a quotation?
Provide the complete order number, required quantity, and destination.