Product Overview
Technical Summary
| Product designation | SIMOTICS M compact synchronous motor |
|---|---|
| Speed and power configuration 1 | 1500 r/min; 101 kW; 643 Nm; 235 A; 271 V |
| Speed and power configuration 2 | 1750 r/min; 117 kW; 638 Nm; 235 A; 315 V |
| Speed and power configuration 3 | 2000 r/min; 118 kW; 563 Nm; 210 A; 355 V |
| Encoder | Incremental SIN/COS 1 VPP, 2048 S/R with C and D track (encoder IC2048S/R) |
| Temperature sensor | KTY 84-130 |
| Ventilation | Forced ventilation, air-flow direction DE–>NDE |
| Degree of protection | IP55 |
| Mounting design | IM B5 with flange A550 (IM V3) |
| Shaft | Fitted key; HALF-KEY balancing |
| Terminal box | Above |
| Cable and signal connections | Cable entry on the right; signal connection D-END |
Key Features
- Motor designation: SIMOTICS M compact synchronous motor.
- Performance configurations: 1500 r/min, 101 kW, 643 Nm, 235 A, 271 V; 1750 r/min, 117 kW, 638 Nm, 235 A, 315 V; 2000 r/min, 118 kW, 563 Nm, 210 A, 355 V.
- Feedback and temperature sensing: Incremental encoder SIN/COS 1 VPP, 2048 S/R with C and D track (encoder IC2048S/R), with temperature sensor KTY 84-130.
- Cooling and protection: Forced ventilation with air-flow direction DE–>NDE; degree of protection IP55.
- Mounting and shaft: Design IM B5 with flange A550 (IM V3); shaft with fitted key and HALF-KEY balancing.
- Connections: Terminal box above, cable entry on the right, and signal connection D-END.
Frequently Asked Questions
Which product does Siemens order number 1PH8224-2MF02-2BA1 identify?
It identifies a SIMOTICS M compact synchronous motor.
Which performance facts should be checked for this exact code?
Check the supplied configurations: 1500 r/min, 101 kW, 643 Nm, 235 A, 271 V; 1750 r/min, 117 kW, 638 Nm, 235 A, 315 V; and 2000 r/min, 118 kW, 563 Nm, 210 A, 355 V.
Which encoder and temperature-sensor details distinguish the variant?
It has an incremental SIN/COS 1 VPP encoder with 2048 S/R, C and D track, encoder IC2048S/R, and temperature sensor KTY 84-130.
What mounting, cooling, protection, and connection details should be checked?
Check forced ventilation with air-flow direction DE–>NDE, IP55 protection, IM B5 with flange A550 (IM V3), the fitted-key shaft, terminal box above, cable entry on the right, and signal connection D-END.
What details are needed to request a quotation?
Provide the complete order number, required quantity, and destination.